Home / Automation / Machine retrofit

Control system retrofit

Modernising a machine with an obsolete PLC

TIVOX Solutions, an industrial engineering company based in Madrid, retrofits machines and lines with obsolete PLCs and operator panels for the food, beverage and pharmaceutical industries in Spain and Portugal. We replace the control system (PLC, HMI, drives and panel) with current technology, with spare parts available and accessible data, and keep the mechanics that work. In phases, during the shutdowns you choose.

When it is needed

The mechanics hold up; the controls do not

Many machines are still sound inside, but depend on a PLC that is no longer manufactured. While it works, nobody touches it; the day it fails, the line stops and there is no spare.

Spare parts

No longer made

PLCs such as the Siemens S5 or S7-300, and many old operator panels, are discontinued. Cards are hunted down on the second-hand market, at a premium.

Program

Nobody can change it

Uncommented programs, no up-to-date backup, or software that no longer runs on today's computers. Every format change becomes a risk.

Data

The machine does not talk

Without communication with the rest of the plant there is no way to measure stoppages or OEE, or to connect machine vision or a cobot.

What we modernise

From the old PLC to current technology

Every machine is different. These are the most common requests; if yours has another brand or model, tell us and we will look into it.

Siemens S5

Migration to the current range

We move the program from an S5 to a current PLC, reviewing the logic rather than copying it blindly, and leave the program commented and documented.

S7-300 and S7-400

Before the CPU fails

We migrate to the current range and use the change to tidy up the program, add diagnostics and get the machine ready to provide data.

Operator panels

Old HMIs

We replace obsolete operator panels with current screens, with clear alarms, recipes per format and history.

Panel and drives

Drives, safety and wiring

When needed, we renew drives, safety devices and the electrical panel, and connect the machine to the plant network.

How we work

From the old machine to an up-to-date machine

The priority is that your production does not suffer. We prepare everything in advance and make the change during the shutdown you choose.

Remote diagnosis

You send us photos of the panel and the PLC rating plate, plus the program backup if you have it. We tell you what needs changing and what does not. If a site visit is needed, travel is quoted separately.

Fixed offer

Fixed scope, price and lead time, with a phased changeover plan.

Program and testing

The new program is prepared and tested before the machine is touched.

Changeover during shutdown

Installation and commissioning in the agreed shutdown window, with real production.

Documentation and warranty

Diagrams, commented program, training for your team and warranty.

FAQ

Answers to the most common questions

Who can modernise an old machine with an obsolete PLC?

TIVOX Solutions, an industrial engineering company based in Madrid. We retrofit machines and lines in the food, beverage and pharmaceutical industries in Spain and Portugal: we replace the PLC, the operator panel and, if needed, the electrical panel and drives, and keep the mechanics that work. Contact: ia@tivoxsolutions.com and +34 914 33 70 71.

What is a machine retrofit?

It means modernising a machine that is still mechanically sound by replacing its control system (PLC, HMI, drives, panel) with current technology. It is cheaper and faster than a new machine and extends its life by many years.

Does my Siemens S5 or S7-300 need replacing now?

If the machine is critical, it is best to plan it before it fails: these PLCs are discontinued and spare parts are scarce and increasingly expensive. When planned, the change is made during a scheduled shutdown; with the machine broken down, it is done in a rush with the line stopped.

Do the mechanics have to be changed?

No. We keep the mechanics that work and only change the controls. If we see something mechanical worth checking, we will tell you, but it is not part of the retrofit unless you ask for it.

How long will the machine be stopped?

As short as possible. The program is prepared and tested in advance, and the change is made in phases, during the shutdowns you decide (a weekend, a summer shutdown). The exact lead time is fixed in the offer.

What if I do not have a copy of the program?

We try to read it from the PLC itself. If that is not possible, we rebuild the program from how the machine works, the diagrams and what your team tells us.

Will I be able to add machine vision or a cobot afterwards?

Yes, and that is one of the advantages. A current PLC communicates with machine vision, with a cobot and with OEE and downtime software.

Let's talk about your machine

Which PLC does your machine have?

Send us a photo of the PLC rating plate and the panel. We will tell you whether it is worth modernising, what would need changing and where to start.